Products

Product Information

50W - 150W YAG Laser Welders

Laser Welders | ML-2450A image

ML-2350A/AF
ML-2351A/AF
ML-2450A

Air Cooling systems are now available!

  • Feature
  • Specification
  • External view
  • Sample
Model ML-2350A ML-2351A ML-2350AF ML-2351AF ML-2450A
Oscillation wavelength 1064nm
Maximum average power 70W 50W 70W 50W 150W
Maximum output energy 70 J/P
(Pulse width 10ms)
50 J/P
(Pulse width 10ms)
70 J/P
(Pulse width 10ms)
50 J/P
(Pulse width 10ms)
70 J/P
(Pulse width 10ms)
Pulse width Standard: 0.3 to 30.0ms (0.1ms steps)
Fine setting: 0.25 to 5.00ms (0.05ms steps)
Standard: 0.3 to 100.0 ms (0.1 ms steps)
Fine setting: 0.25 to 5.00 ms (0.05 ms steps)
Pulse repetition 1 to 200pps
No. of programmable schedules 32
Counter Total number of outputs 9 digits
Number of acceptable outputs 9 digits
Fiber optic delivery Up to 4 energy - sharing fiber deliveries or up to 6 time- sharing fiber deliveries(Option)
External communication function RS-485
Power requirements 3-phase, 200, 240, 380, 400 V
AC±10%, 50/60Hz

3-phase, 220 V
AC+10%-15%, 50/60Hz
(Tap switching)
3-phase, 200, 380, 400 V
AC±10%, 50/60Hz

3-phase, 220 V
AC+10%-15%, 50/60Hz
(Tap switching)
3-phase, 200, 240, 380, 400 V AC±10%, 50/60Hz

3-phase, 220 V AC+10%-15%, 50/60Hz
(Tap switching)
Cooler Heat exchange method Water - Water Forced air-cooled Water - Water
Required city water Pressure: 294kPa (3kgf/cm²) maximum Pressure: 294kPa (3kgf/cm²) maximum
Water temperature: 5° to 32°C Water temperature: 5° to 32°C
Flow rate: 4 litter/min at 25°C Flow rate: 9 litter/min at 25°C
18 litter/min at 32°C 25 litter/min at 32°C
Differential Pressure: 98 to 294kPa (1 to 3kgf/cm²) Differential Pressure: 98 to 294kPa (1 to 3kgf/cm²)
Dimensions 495(W) X 995(D) X 990(H)mm 521(W) X 995(D) X 990(H)mm 495(W) X 995(D) X 990(H)mm
Weight Approx. 210 kg
(at 200, 220 V AC)
Approx. 220 kg
(at 200, 220 V AC)
Approx. 230 kg
(at 200, 220 V AC)
Approx. 240 kg
(at 240,380, 400 V AC)
Approx. 250 kg
(at 380,400 V AC)
Approx. 250 kg
(at 240, 380, 400 V AC)

Specifications subject to change without notice.

  • Feature
  • Specification
  • External view
  • Sample